1″ Manifold with Thermostat Insert
In hot/cold water installation systems, it ensures that the water coming from the feeder is distributed to other lines in the system or collected from other lines in the system.
Technical Data Sheet
Product Name | 1″ Manifold with Thermostat Insert |
Standard | TSE K 534 / TSEK |
Max. Working Temperature | 120°C |
Pressure Class | PN 10 |
Intended Use | Heating Systems |
Product Code (1816…
Dim. | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 | 510 | 511 | 512 | 513 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Hole | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 |
D1 | 1” | 1” | 1” | 1” | 1” | 1” | 1” | 1” | 1” | 1” | 1” | 1” |
D2 | M30x1.5 | M30x1.5 | M30x1.5 | M30x1.5 | M30x1.5 | M30x1.5 | M30x1.5 | M30x1.5 | M30x1.5 | M30x1.5 | M30x1.5 | M30x1.5 |
L1 | 114 | 161 | 208 | 255 | 302 | 349 | 396 | 443 | 490 | 537 | 584 | 631 |
L2 | 47 | 47 | 47 | 47 | 47 | 47 | 47 | 47 | 47 | 47 | 47 | 47 |
H | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 |
SW1 | 22 | 22 | 22 | 22 | 22 | 22 | 22 | 22 | 22 | 22 | 22 | 22 |
SW2 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 |
SW3 | 39 | 39 | 39 | 39 | 39 | 39 | 39 | 39 | 39 | 39 | 39 | 39 |
Technical Drawings
Documents
Installation and Operating Instructions
- Make sure there is no damage on the product may occur during transport and shipping. Before assembly do not unpack the product in order to prevent from the external effects.
- Clean all kinds of contaminants before assembly.
- Make sure that the thread length to be connected to the manifold is not too short or too long than the thread length of the manifold.
- Install the Manifold to the system by the appropriate tools.
- First, install the Nut,Ring and Socket to the hose, then screw the nut to the manifold by the appropriate tools.
- Make sure the hose to be connected to the manifold is the correct size(16×2/17×2).
- Observe the axiality during assembly.
- The installation system that manifold connected must be protected against the freezing.
- Manifold is suitable for use in heating systems and should not be used in flammable or combustible gas/liquid installations.
- Do not paint the manifold, do not expose the manifold with abrasive chemicals, do not open or close with any other tool and do not remove the handle.